MAX. FLUID TEMP.
212°F

MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
BRONZE SOLENOID VALVE
TYPE "A" FULL PORT
NORMALLY CLOSED - 1/2" TO 3" PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2” NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18” leads - (Class H available)

APPLICATION:
To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top.

Pipe
Size
Inches
Max.
Diff.
PSI
Type No.
Watts
AC
Amps
Hold
120-60
Amps Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A
B
C
D
D
(Flanged)
150#
1/2
110
25
0.4
1.2
18
8
7
5-7/8
2-3/4
3-1/4
4-3/4
200
300
N/A
500
45
0.8
2.4
23
16
8
6-7/8
4-1/8
3-1/4
3/4
50
25
0.4
1.3
18
8
7-1/8
6
2-3/4
3-1/2
5-1/2
110
160
40
0.6
2.0
28
200
45
0.8
2.6
23
12
8-1/8
7
3-1/2
3-1/2
300
N/A
500
65
1.2
3.9
33
17
8-1/8
7
4-1/8
3-1/2
1
50
25
0.4
1.5
18
10
7-7/8
6-5/8
2-3/4
4-1/8
5
110
160
40
0.6
2.3
28
200
45
0.8
2.8
23
14
8-7/8
7-1/2
4-1/8
4-1/8
300
N/A
500
65
1.2
4.2
33
19
8-7/8
7-1/2
4-1/8
4-1/8
1-1/4
50
25
0.4
1.6
18
12
8-3/8
6-3/4
2-3/4
4-1/2
7
90
150
40
0.6
2.4
28
200
45
0.8
3.0
23
16
9-3/8
7-3/4
3-1/2
4-1/2
300
N/A
500
60
1.2
6.2
N/A
20
10-3/8
8-3/4
4-1/2
4-1/2
1-1/2
50
45
0.8
3.2
23
20
10
8-1/8
4
4-7/8
7-3/4
115
160
65
1.2
4.8
33
200
60
1.2
6.7
35
24
11
9-1/8
4-1/2
4-7/8
300
N/A
500
85
2.0
10.0
45
2
50
45
0.8
3.5
23
31
11
8-3/4
5-3/8
6
8
100
150
65
1.2
5.0
33
200
60
1.2
7.4
35
36
12
9-3/4
5-3/4
6
300
N/A
500
85
2.0
11.0
45
2-1/2
50
60
1.2
8.0
35
43
12-7/8
10-1/8
5-7/8
7-1/4
11
125
200
300
85
2.0
12.0
45
N/A
3
50
60
1.2
8.8
35
56
13-3/4
10-1/2
6-5/8
8-3/8
9-1/2
100
200
300
85
2.0
13.0
45
N/A
Strainers are recommended
for use with solenoid valves. Click here to link to the Strainers page.


When you order please supply the following:


• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features

Click here to link to the Optional Features page.

†† Not available for DC operation